IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Trichloromethane (chloroform) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Trichloromethane (chloroform); CHCl3; [67-66-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Ababi, V.; Popa, A.; Mihaila, Gh. Analele Stiint., Univ. Al. I. Cuza Iasi. Sect. IC. Chem. 1964, 10, 71-84.

Variables:
   Temperature = 294 K

Prepared By:
   Z. Maczynska

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1103 * Mole Fraction x1 (compiler)102 * w1/M1 (compiler) [mol g**-1]
20.50.71.45.86 x 10-3
Method/Apparatus/Procedure:
   The isothermic titration method described by Ababi and Popa (refs. 1, 2) was used. A trichloro-methane-water-allyl alcohol ternary system was also studied. Further details are not available in the article.

Source and Purity of Materials:
   (1) Source and purity not given, nD = 1.4454 at 20oC.
   (2) Distilled (compiler).

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.1 K.

References:
   1 Ababi, V.; Popa, A. Analele Stiint. Univ. Al.I. Cuza Iasi. Sect. I, 1960, IV, 929.
   2 Ibid., 1960, VIII, 233.