IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Trichloromethane (chloroform) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Trichloromethane (chloroform); CHCl3; [67-66-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Lowe, H.J. in Theory and Application of Gas Chromatography, Kroman, H.S.; Bender, S.R., Eds., Grune and Stratton, New York, 1968, p. 194-209.

Variables:
   Temperature = 310 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°COstwald coefficient, L /dimensionless102 * Mass Fraction w1 (compiler) 103 * Mole Fraction x1 (compiler)
373.800.7531.14
Method/Apparatus/Procedure:
   The direct injection technique was used for the investigation of the solubility of trichloromethane in water. Ostwald coefficients were determined by equilibration of trichloromethane with water in a capped syringe. After thoroughly mixing, a sample was withdrawn and  analyzed in a gas chromatograph equipped with a hydrogen flame detector. The concentration was proportional to the recorded peak height.

Source and Purity of Materials:
   (1) Source and purity not given.
   (2) Distilled.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 1 K (compiler).