IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Trichloromethane (chloroform) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Trichloromethane (chloroform); CHCl3; [67-66-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Okuda, Y., Arch. Jap. Chir. 1968, 37, 700-16.

Variables:
   Temperature = 288 K - 313 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°COstwald coefficient, L /dimensionless102 * Mass Fraction w1 (compiler) 104 * Mole Fraction x1 (compiler)
157.15 +/- 2.030.59158.971
205.95 +/- 1.350.60929.241
255.08 +/- 0.830.63789.677
304.40 +/- 0.530.671710.195
353.85 +/- 0.400.709110.766
373.70 +/- 0.390.750111.392
403.40 +/- 0.340.749911.389
Method/Apparatus/Procedure:
   A gas chromatographic analysis combined with a crushed ampoule technique was used. The solubility values were determined by equilibrating trichloromethane with water in a sealed ampoule. Then, after the ampoules were broken, the samples were analyzed using a gas  chromatograph equipped with a flame ionization detector.

Source and Purity of Materials:
   (1) Source and purity not given.
   (2) Distilled (compiler).

Estimated Errors:
   Solubility: See above.
   Temperature: ± 0.5 K (compiler).