IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Trichloromethane (chloroform) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Trichloromethane (chloroform); CHCl3; [67-66-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Antropov, L.I.; Populyai, V.E.; Simonov, V.D.; Shamsutdinov, T.M., Russ. J. Phys. Chem. 1972, 46, 311-2 (VINITI No. 3739-71).

Variables:
   Temperature = 288 K - 299 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1102 * Mass Fraction w2103 * Mole Fraction x1 (compiler)103 * Mole Fraction x2 (compiler)
151.0-1.52-
18-6.2 x 10-2-4.09
22-6.5 x 10-2-4.29
26-7.9 x 10-2-5.21
Method/Apparatus/Procedure:
   The Alexejev's synthetic method of solubility determination was used (ref. 1). A fixed weight of trichloromethane and water was sealed in a tube and subjected to gradually increasing temperature with constant agitation. The appearance of opalescence or clouding  was the indication of the saturation temperature. The temperature was then allowed to fall and, while the tube was constantly agitated, the temperature of the first appearance of opalescence was recorded. The observation was repeated several times.

Source and Purity of Materials:
   (1) Source and purity not given.
   (2) Distilled.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 1 K (compiler).

References:
   1 Alexejev, W. Ann. Phys. Chem. 1886, 28, 305.