IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Iodomethane with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Iodomethane; CH3I; [74-88-4]  NIST Chemistry WebBook for detail

Original Measurements:
   Swain, C.G.; Thornton, E.R., J. Am. Chem. Soc. 1962, 84, 822-6.

Variables:
   Temperature = 303 K - 313 K
   Pressure = 303 K - 313 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°CHenry's law constant [m**3 atm mol**-1]102 * Mass Fraction w1 (compiler) 103 * Mole Fraction x1 (compiler)P1 c-1 [dm**-3 mmHg mol**-1]
29.446.421 x 10-31.3971.7934880
29.456.447 x 10-31.3921.7884900
40.349.013 x 10-31.4781.9006850
40.359.105 x 10-31.4631.8816920
Method/Apparatus/Procedure:
   The measuring apparatus was described by Brown et al. (ref. 1). Iodomethane gas was admitted to the measurement apparatus from a storage bulb by distillation. The gas volume absorbed by water was determined using a gas buret. The temperature was controlled  by a water bath and the equilibrium was aided by a magnetic stirrer in the equilibration bulb. The concentration in the solution was calculated from the pressure and volume measured.

Source and Purity of Materials:
   (1) Eastman Kodak Co., redistilled before use.
   (2) Double distilled.

Estimated Errors:
   Solubility: ± 3 %.
   Temperature: ± 0.01 K.
   Pressure: ± 0.05 mmHg.

References:
   1 Brown, H. C.; Taylor, M. D.; Gerstein, M. J. Am. Chem. Soc. 1944, 66, 431.