IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Tetrachloromethane (carbon tetrachloride) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Tetrachloromethane (carbon tetrachloride); CCl4; [56-23-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Staverman, A.J., Recl. Trav. Chim. Pays-Bas 1941, 60, 836-41.

Variables:
   Temperature = 273 K - 303 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1105 * Mole Fraction x1 (compiler)102 * w1/M1 (compiler) [mol g**-1]
0.50 x 10-242.82.77 x 10-4
251.16 x 10-299.16.44 x 10-4
301.58 x 10-2135.08.77 x 10-4
Method/Apparatus/Procedure:
   Tetrachloromethane was shaken with water for about 12 hours in a liquid paraffin thermostat bath. The water content of the organic phase was determined by the Karl Fischer titration method. All measurements were done in duplicates. The results were averages of  two measurements at each temperature. A full description of the method used is given in a Ph. D. thesis (ref. 1).

Source and Purity of Materials:
   (1) Distilled.
   (2) Source and purity not given.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.5 K (compiled).

References:
   1 Staverman, A. J. Ph. D. Thesis, Univ. of Leiden, Leiden, Belgium, 1938.