IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Tetrachloromethane (carbon tetrachloride) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Tetrachloromethane (carbon tetrachloride); CCl4; [56-23-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Orlandini, M.; Fermeglia, M.; Kikic, I.; Alessi, P., Chem. Eng. J. 1983, 26, 245-50.

Variables:
   Temperature = 293 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1 (compiler) 102 * Mass Fraction w2 (compiler)104 * Mole Fraction x1104 * Mole Fraction x2
207.68 x 10-28.322 x 10-30.97.1
Method/Apparatus/Procedure:
   A mixture of water and tetrachloromethane was agitated overnight and left at equilibrium for 24 hours. Three samples were withdrawn from each phase with a syringe and analyzed by gas chromatography. The gas chromatograph (C. Erba ATc/t) was equipped with  a Shimadzu Chromatopac E-1A integrator. A stainless column packed with 100-120 mesh Chromosorb W DMCD coated with heptadecane nitrile was used for analysis.

Source and Purity of Materials:
   (1) Fluka reagent, purified by distillation before use.
   (2) Distilled (compiler).

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.1 K.