IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Tetrachloromethane (carbon tetrachloride) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Tetrachloromethane (carbon tetrachloride); CCl4; [56-23-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Lo, J.M.; Tseng, C.L.; Yang, J.Y., Anal. Chem. 1986, 58, 1596-7.

Variables:
   Temperature = 298 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C102 * Mass Fraction w1105 * Mole Fraction x1102 * w1/M1 (compiler) [mol g**-1]
258.0 x 10-29.385.20 x 10-4
Method/Apparatus/Procedure:
   A 5 ml tetrachloromethane sample containing a labeled complex, cobalt(III) pyrrolidinecarbodithioate, was placed together with 1000 ml water into a separation funnel. After rigorous shaking of the funnel for 5 minutes the mixture was left for 30 minutes before separation  of the two phases. Samples were withdrawn for activity measurement using a NaI (Tl) scintillation detector. Several factors were adjusted to obtain accurate measurements.

Source and Purity of Materials:
   (1) E. Merck Co., used as received.
   (2) Demineralized and then boiled at reduced pressure.

Estimated Errors:
   Solubility: ± 0.7 x 10-2 std. dev.
   Temperature: ± 1.0 K (compiler).