IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Tetrachloromethane (carbon tetrachloride) with Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Tetrachloromethane (carbon tetrachloride); CCl4; [56-23-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Howe, G.B.; Mullins, M.E.; Rogers, T.N., AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).

Variables:
   Temperature = 283 K - 303 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C106 * Mass Fraction w1102 * Mass Fraction w1 (compiler) 105 * Mole Fraction x1 (compiler)
101041.04 x 10-21.218
201461.46 x 10-21.710
301051.05 x 10-21.230
Method/Apparatus/Procedure:
   250 ml bottles were filled with distilled and deionized water and sealed. A measured volume of tetrachloromethane was injected into the bottles through each septum using a microliter syringe. Tetrachloromethane was in excess of the anticipated solubility  limit. The bottles were shaken for one hour with a wristaction shaker and allowed to equilibrate for about 3 weeks. Samples were then injected into a gas chromatograph equipped with a Carbopack column and a FID detector. The GC response was compared with calibrations plots.

Source and Purity of Materials:
   (1) Source not given. Probably a commercial reagent, at least 99 % purity. Used as received.
   (2) Distilled and deionized.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.5 K (compiler).