IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Carbon dioxide with Calcium chloride and Water

Components:
   (1) Calcium chloride; CaCl2; [10043-52-4]  NIST Chemistry WebBook for detail
   (2) Carbon dioxide; CO2; [124-38-9]  NIST Chemistry WebBook for detail
   (3) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Malinin, S. D.; Savelyeva, N. I., *Geokhimiya 1972, (6), 643-53; Geochem. Int. 1972, 9, 410-8.

Variables:
   Temperature = 293.15 K to 353.15 K
   Pressure = 293.15 K to 353.15 K
   Concentration = c2/mol L-1 = 0 - 3.854

Prepared By:
   C.L. Young

Experimental Data:   (Subscripts 1,2,3, ..., in column headings refer to components 1,2,3, ...)
  
T/KPressure [bar]Concentration C1Concentration NoteConcentration C2 [mol/L]Keunen coefficient, SS Note
293.1547.9552.84a0.0052.84b
293.1547.9541.37a0.43752.84b
293.1547.9542.20+a0.43752.84b
293.1547.9533.59+a0.87952.84b
293.1547.9526.80a1.34952.84b
293.1547.9526.71a1.34952.84b
293.1547.9516.84+a2.34152.84b
293.1547.9516.81+a2.34152.84b
293.1547.9510.49a3.44352.84b
293.1547.9510.47a3.44332.86b
323.1547.9532.86a0.0027.63b
323.1547.9526.39a0.43726.33b
323.1547.9524.84+a0.553126.33b
323.1547.9524.82+a0.553119.68b
323.1547.9517.14a1.34916.01b
323.1547.9513.19a1.93516.01b
323.1547.9513.19a1.93513.96b
323.1547.9511.07a2.35413.96b
353.1547.9523.92a0.0023.92b
353.1547.9522.01a0.155422.46b
353.1547.9522.15a0.155422.46b
353.1547.9515.33+a0.876616.86b
353.1547.9515.36+a0.876616.86b
353.1547.9513.84+a1.17315.37b
353.1547.9530.60+a1.17315.37b
353.1547.9512.88+a1.28314.70b
353.1547.9512.68+a1.28314.70b
353.1547.959.05a2.09911.16b
353.1547.954.58a3.8546.69b
Notes:
   +  Equilibrium state approached from supersaturation
   a  Solubility of CO2: C1 = m1 (in grams) / 1 kg of solution
   b  Solubility of CO2: S1 = m1 (in grams) / 1 kg of water

Method/Apparatus/Procedure:
   Flow system with about 0.25 L of solution in 0.5 L stainless steel cell. After equilibrium established, liquid sampled and carbon dioxide absorbed in potassium hydroxide. Gain in weight of absorption train used to estimate amount of carbon dioxide. Details in source.

Source and Purity of Materials:
   (1) GOST 8050-64 sample.
   (2) Analytical reagent grade sample.
   (3) No details given.

Estimated Errors:
   Solubility: δC1, δS1 = ± 0.5 % (estimated by the compiler)
   Temperature: δT/K = ± 0.1 (estimated by compiler)
   Pressure: δP/bar = ± 0.1 (estimated by the compiler)