IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Carbon dioxide with Calcium chloride and Water

Components:
   (1) Calcium chloride; CaCl2; [10043-52-4]  NIST Chemistry WebBook for detail
   (2) Carbon dioxide; CO2; [124-38-9]  NIST Chemistry WebBook for detail
   (3) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Yasunishi, A.; Yoshida, F., J. Chem. Eng. Data 1979, 24, 11-14.

Variables:
   Temperature = 298.15 K and 308.15
   Pressure = 298.15 K and 308.15
   Concentration = c2/mol L-1 = 0 - 4.528

Prepared By:
   C.L. Young

Experimental Remarks:

   P = 1 atm = 101.325 kPa = 1.01325 bar

Experimental Data:   (Subscripts 1,2,3, ..., in column headings refer to components 1,2,3, ...)
  
T/KOstwald coefficient LOstwald NoteConcentration C2 [mol/L]
298.150.8264a0
298.150.7458a0.227
298.150.6477a0.558
298.150.5434a0.893
298.150.4701a1.237
298.150.4118a1.601
298.150.3380a2.008
298.150.2969a2.396
298.150.2544a2.809
298.150.2026a3.486
298.150.1876a3.801
298.150.1705a4.528
308.150.6675a0
308.150.5786a0.295
308.150.4742a0.807
308.150.4708a0.809
308.150.4010a1.283
308.150.2864a2.137
Notes:
   a  L = Ostwald coefficient (cm3 cm-3)

Method/Apparatus/Procedure:
   Volumetric apparatus with multibulb buret and magnetic stirrer. Amount of solution and gas absorbed determined volumetrically. Density and composition of solution determined after absorption. Details in Ref. 1.

Source and Purity of Materials:
   (1) High purity grade sample, purity 99.96 mole %.
   (2,3) Guaranteed reagent, solution degassed by boiling.

Estimated Errors:
   Solubility: δL = ± 1 %
   Temperature: δT/K = ± 0.05

References:
   1. Tokunaga, J.
J. Chem. Eng. Data 1975, 20, 41.