Solubility System:
Carbon dioxide with Barium chloride and Water
Components:
(1) Barium chloride; BaCl2; [10361-37-2]
NIST Chemistry WebBook
for detail
(2) Carbon dioxide; CO2; [124-38-9]
NIST Chemistry WebBook
for detail
(3) Water; H2O; [7732-18-5]
NIST Chemistry WebBook
for detail
Original Measurements:
Setchenow, J. [Sechenov, I.M.], Nouv. Mem. Soc. Imp. Nat. Moscow 1889, 15, 203-74.
Variables:
Temperature = 288.35 K
Concentration =
c
2
/mol dm
-3
= 0 - 1.590
Prepared By:
Pirketta Scharlin
Experimental Remarks:
Initial solution: 33.106 BaCl
2
+ 97.06 cm
3
water to make 100 cm
3
of solution (saturated solution).
Experimental Data:
(Subscripts 1,2,3, ..., in column headings refer to components 1,2,3, ...)
t/°C
T/K
Temp Note
Dilution
Concentration C
2
[mol/dm
3
]
Concentration Note
α
α Note
Salt Effect [dm
3
/mol]
Salt Note
15.2
288.35
a
∞
0
a
1.009
b
-
a, c
15.2
288.35
a
1
1.590
a
0.479
b
0.203
a, c
Notes:
a
Calculated by the compiler.
b
α = Bunsen coefficient [cm
3
(STP) cm
-3
atm
-1
].
c
K
scc
= Setchenow salt effect parameter;
K
scc
= (1/
c
2
) lg(α°/α).
Method/Apparatus/Procedure:
Setchenow (Ref. 1) based his apparatus on those of Fernet (1857) and of Meyer (1857). The manometer was based on ideas he learned from Regnault in 1861. The one meter manometer had three branches, two for measuring the pressure and one a mercury reservoir. The manometer was connected to the absorption cell by a flexible silver capillary. The absorption cell was of two bulbs with a mark in the constricting connection. CO
2
gas was generated, saturated with water vapor and filled the bulbs and manometer to a known pressure less than atmospheric. The liquid was degassed by heating and then passed by the pressure difference into the lower bulb to the mark of known volume. The system was sealed, turned 90 degrees and shaken until equilibrium was established. The gas volume absorbed was reduced to 0 °C and one meter Hg pressure. The Bunsen coefficient was calculated.
Source and Purity of Materials:
(1) Apparently generated from limestone and sulfuric acid. Dried.
(2) Not specified.
(3) Not specified, assumed to be distilled.
Estimated Errors:
Temperature: The author makes a qualitative statement that the results are good to the second decimal.
References:
1. Setchenow, J., Akad. Nauk. SSR Mem. Acad. Imp. Sci. St. Petersburg 1887, 35, [Ser. No. 7], 1-59.