Solubility System:
Carbon dioxide with Sodium chloride, Nitric acid and Water
Components:
(1) Sodium chloride; NaCl; [7647-14-5]
NIST Chemistry WebBook
for detail
(2) Nitric acid; HNO3; [7697-37-2]
NIST Chemistry WebBook
for detail
(3) Carbon dioxide; CO2; [124-38-9]
NIST Chemistry WebBook
for detail
(4) Water; H2O; [7732-18-5]
NIST Chemistry WebBook
for detail
Original Measurements:
Onda, K.; Sada, E; Kobayashi, T.; Kito, S.; Ito, K., J. Chem. Eng. Jpn 1970, 3, 137-42.
Variables:
Temperature = 298.15 K
Pressure = 101.325 kPa
Concentration =
c
2
/mol L
-1
= 0 - 1.397
c
3
/mol L
-1
= 0 - 0.766
Prepared By:
C.L. Young
Experimental Remarks:
P
= 1 atm= 1.01325 x 10
5
Pa
Experimental Data:
(Subscripts 1,2,3, ..., in column headings refer to components 1,2,3, ...)
T/K
Concentration C
2
[mol/L]
Concentration C
3
[mol/L]
α
α Note
Ionic Strength [mol/L]
Ionic Note
298.15
0
0
0.7595
a
0
a
298.15
0.557 (b)
0.840 (b)
06865
a
1.397
a
298.15
1.175 (b)
1.771 (b)
0.6241
a
2.946
a
298.15
0.411 (c)
0.226 (c)
0.6898
a
0.637
a
298.15
1.140 (c)
0.626 (c)
0.5953
a
1.766
a
298.15
1.397 (c)
0.766 (c)
0.5661
a
2.163
a
Notes:
(a)
Quoted in original paper.
I
= ionic strength; α = Bunsen coefficient [cm
3
(STP) cm
-3
atm
-1
].
(b)
Calculated from ratio of ionic strength NaCl:HNO
3
being 0.3988:0.6012 as quoted in original paper.
(c)
Calculated from ratio of ionic strength NaCl:HNO
3
being 0.6458:0.3542 as quoted in original paper.
Method/Apparatus/Procedure:
Concentrated solution prepared by weighting, less concentrated solutions prepared by dilution. Equilibrium established between a measure volume of gas and a measured amount of gas-free liquid in a cell fitted with a magnetic stirrer. Amount of gas absorbed estimated from change in volume of gas. Details in source and Ref. (1).
Source and Purity of Materials:
(1) Commercial sample, purity 99.8 mole %.
(2) analytical grade sample.
(3) No details given.
Estimated Errors:
Solubility: δα = ± 2 % (estimated by the compiler)
Temperature: δ
T
/K = ± 0.2 (estimated by compiler)
References:
Onda, K.; Sada, E.; Kobayashi, T.; Kito, S.; Ito, K., J. Chem. Eng. Jpn. 1970, 3, 18.