Experimental Data:   (Subscripts 1,2,3, ..., in column headings refer to components 1,2,3, ...)
  
T/KTemp NotePressure [atm]Keunen coefficient, SS NoteMole Fraction (x1)
273a10.7016.79b1.332
273a15.7422.93b1.810
273a29.4733.72b2.639
298a10.987.66b0.617
298a11.037.75b0.6234
298a22.9215.51b1.2399
298a24.6615.91b1.2714
298a24.7716.08b1.2849
298a26.0016.81b1.3427
298a31.4019.54b1.5570
298a34.4120.88b1.662
298a38.8323.34b1.8541
298a39.1823.46b1.8635
298a44.1025.66b2.0348
298a45.0525.70b2.0378
298a56.1029.05b2.297
298a62.930.42b2.4032
323a19.147.75b0.623
323a32.5812.31b0.987
323a32.7912.49b1.001
323a46.8015.93b1.2730
323a46.8816.32b1.304
323a57.0019.11b1.5233
323a60.3020.05b1.5970
323a60.9220.30b1.6166
323a61.1020.39b1.6236
323a62.0020.52b1.6338
323a73.2222.59b1.7957
323a73.8223.27b1.8487
323a74.5023.00b1.8277
323a89.6026.00b2.0611
323a91.5025.68b2.0363
323a92.0025.86b2.0503
348a18.845.48b0.441
348a19.005.38b0.434
348a32.248.96b0.724
348a32.689.05b0.7272
348a46.6112.26b0.983
348a60.2715.24b1.2185
348a60.9215.06b1.2043
348a61.0315.11b1.2083
348a61.2215.25b1.2193
348a75.7017.62b1.4062
348a75.9518.00b1.4360
348a76.3517.83b1.4227
348a92.0520.17b1.6064
373a93.2220.33b1.6111
373a19.104.30b0.3477
373a19.274.29b0.3460
373a32.077.13b0.5738
373a32.587.33b0.5895
373a32.697.23b0.582
373a32.787.18b0.5778
373a46.109.98b0.8013
373a46.7510.13b0.813
373a46.899.89b0.7942
373a60.9512.24b0.9810
373a61.3013.52b1.0825
373a75.0018.17b1.448
373a90.0018.17b1.448
Notes:
   a  Calculated by the compiler.
   b  S1 = solubility of CO2 in water [cm3 (STP) cm-3]

Method/Apparatus/Procedure:
   The saturation of water with CO2 was achieved in a thermostatted rocking autoclave with inner walls plated with silver. CO2 solubility was determined by measuring the volume of the gas desorbed from the solutions under ambient conditions. The equipment was similar to that used in Ref. 1.

Source and Purity of Materials:
   Nothing specified.

Estimated Errors:

   Temperature: Nothing specified.

References:
   1. Wiebe, R.; Graddy, V.L.; Heins, Jr. C., Ind. Eng. Chem. 1932, 24, 823.