IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Carbon dioxide with Ammonium chloride and Water

Components:
   (1) Ammonium chloride; NH4Cl; [12125-02-9]  NIST Chemistry WebBook for detail
   (2) Carbon dioxide; CO2; [124-38-9]  NIST Chemistry WebBook for detail
   (3) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Burmakina, G.V.; Efanov, L.N.; Shnet, M.A., *Zh. Fiz. Khim. 1982, 56, 1159-61; Russ. J. Phys. Chem. (Engl. Transl.) 1982, 56, 705-7.

Variables:
   Temperature = 298.15 K
   Pressure = 0.1 MPa
   Concentration = 103c2/mol L-1 = 0 - 1000

Prepared By:
   Yu. P. Yampol'skii

Experimental Data:   (Subscripts 1,2,3, ..., in column headings refer to components 1,2,3, ...)
  
T/K103 * Concentration C1 [mol/L]Concentration Note103 * Concentration C2 [mol/L]Concentration Note
298.1533.90c0b
298.1533.85c1b
298.1533.70c2b
298.1533.50c5b
298.1533.00c10b
298.1532.50c25b
298.1532.00c50b
298.1531.00c100b
298.1530.20c250b
298.1529.15c500b
298.1528.15c1000b
Notes:
   a  Data taken from a graph by compiler.
   b  c2 = concentration of NH4Cl
   c  c1 = concentration of CO2

Method/Apparatus/Procedure:
   Attainment of the equilibrium was checked by the constancy of CO2 content in 3-5 subsequent samples of gas after saturation of the solution. The concentration of carbon dioxide was determined by titration.

Source and Purity of Materials:
   (1) Source not given. Before contacting with water solutions CO2 was allowed to pass through the vessels with NaHCO3, glass beads, glass wool, and distilled water.
   (2) Nothing specified.
   (3) Distilled.

Estimated Errors:
   Solubility: δc1/c1 = ± 0.06 - 0.2 %
   Temperature: δT/K = ± 0.05