IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: 1,1,2,2-Tetrachloroethane with Water.

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) 1,1,2,2-Tetrachloroethane; C2H2Cl4; [79-34-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Leighton, D.T.; Calo, J.M., J. Chem. Eng. Data 1981, 26, 382-5.

Variables:
   Temperature = 284 K - 300 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°CDistribution coefficient, DL102 * Mass Fraction w1 (compiler) 104 * Mole Fraction x1 (compiler)
11.010.940.19432.0892
13.012.520.19672.1150
21.017.030.25382.7305
22.019.400.23842.5647
27.220.940.30693.3030
Notes:
   a  Gas-liquid system analysis parameter, from calibration measurements.

Method/Apparatus/Procedure:
   A 5 μL 1,1,2,2-tetrachloroethane sample was injected into a 2.3 dm3 equilibration cell containing distilled water. After the cell was shaken vigorously for about 5 minutes, the homogeneity of the liquid sample was maintained with a  magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The 1,1,2,2-tetrachloroethane content was extracted and analyzed using a dual flame ionization detector gas chromatograph.

Source and Purity of Materials:
   (1) Source and purity not given.
   (2) Distilled.

Estimated Errors:
   Solubility: ± 5.6.
   Temperature: ± 0.5 K.