IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: 1,1,2,2-Tetrachloroethane with Water.

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) 1,1,2,2-Tetrachloroethane; C2H2Cl4; [79-34-5]  NIST Chemistry WebBook for detail

Original Measurements:
   Howe, G.B.; Mullins, M.E.; Rogers, T.N., AFESC Tyndall Air Force Base, Report ESL-TR-86-66, Vol. 1, Florida, Sept. 1987, 86 pp. (AD-A188 571).

Variables:
   Temperature = 283 K - 303 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C106 * g1/g2102 * Mass Fraction w1 (compiler) 104 * Mole Fraction x1 (compiler)
1025880.25882.7841
2025600.25262.7173
3021310.21312.2916
Method/Apparatus/Procedure:
   250 cm3 bottles were filled with distilled, deionized water and sealed. Measured volumes of 1,1,2,2-tetrachloroethane were injected into the bottles through each bottle septum using a microliter syringe. The solute was in excess  of the anticipated solubility limit. The bottles were shaken for 1 hour with a wrist-action shaker and allowed to equilibrate for about three weeks. Samples were then injected into a gas chromatograph equipped with a Carbo-pack column and a FID detector. The GC responses were compared with calibration plots to establish concentrations.

Source and Purity of Materials:
   (1) Probably a commercial reagent, at least 99 % pure, used as received.
   (2) Distilled and deionized.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.5 K (compiler).