IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Water with 1,2-Dichloroethane.

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) 1,2-Dichloroethane; C2H4Cl2; [107-06-2]  NIST Chemistry WebBook for detail

Original Measurements:
   Davies, W.; Jagger, J.B.; Whalley, H.K., J. Soc. Chem. Ind. (London) 68, 26 (1949).

Variables:
   Temperature = 253 K - 353 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°C103 * Mass Fraction w1103 * Mole Fraction x1 (compiler)102 * w1/M1 (compiler) [mol g**-1]
-200.52.72.8 x 10-3
-100.73.83.9 x 10-3
01.05.45.6 x 10-3
101.37.17.2 x 10-3
201.79.39.4 x 10-3
302.212.01.22 x 10-2
402.915.71.6 x 10-2
503.720.02.1 x 10-2
604.825.82.7 x 10-2
706.032.13.3 x 10-2
807.539.84.2 x 10-2
Method/Apparatus/Procedure:
   A mixture of water and 1,2-dichloroethane was agitated in a flask until equilibrium was established. The apparatus was assembled in a waterbath thermostat. The equilibrium was established after 30 minutes. The pipette used for withdrawing samples  from the mixture was fitted with a cotton wool filter at the tip to prevent ice particles from being withdrawn at low temperatures. The solvent layer was titrated with Karl Fischer reagent.

Source and Purity of Materials:
   (1) Commercial quaility, source not given.
   (2) Distilled.

Estimated Errors:
   Solubility: ± 5 %.
   Temperature: ± 0.5 K(compiler).