IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Tetrachloroethene (tetrachloroethylene) with Water.

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) Tetrachloroethene (tetrachloroethylene); C2Cl4; [127-18-4]  NIST Chemistry WebBook for detail

Original Measurements:
   Mackay, D. et al. Volatilization of Organic Pollutants from Water, U. S. EPA Report 600/2-82-019, Athens, Georgia, 1982, (PB 82-230939).

Variables:
   Temperature = 293 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°CDensity ρ [kg m**-3]102 * Mass Fraction w1 (compiler) 105 * Mole Fraction x1 (compiler)
200.4004.00 x 10-24.347
Method/Apparatus/Procedure:
   An aqueous solution with an excess amount of tetrachloroethene was stirred for one day before being introduced into a one liter glass vessel. Nitrogen entered at the bottom of the vessel through a sintered glass disk. The exit gas flow rate was  measured by a soap bubble flow meter. The concentration of tetrachloroethene in water was determined by gas chromatography. The GC was equipped with both a dual flame ionization detector and an electron capture detector.

Source and Purity of Materials:
   (1) Source and purity not given.
   (2) Doubly distilled.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 1.0 K.