Glass Ball as Bullet Solubility System: Water with 1,2-Dichloroethane.

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) 1,2-Dichloroethane; C2H4Cl2; [107-06-2]  NIST Chemistry WebBook for detail

Original Measurements:
   Prosyanov, N.N.; Shalygin, V.A.; Zel'venskii, Ya.D., Tr. Mosk. Khim.-Technol. Inst. 100 (1973).

Variables:
   Temperature = 296 K - 352 K

Prepared By:
   A. L. Horvath

Experimental Data:   (Notes on the Nomenclature)
  
t/°CDistribution coefficient, DL102 * Mass Fraction w1 (compiler) 103 * Mole Fraction x1 (compiler)
2324.92.07 x 10-21.14
2524.72.31 x 10-21.27
5016.71.34 x 10-17.30
6514.63.12 x 10-116.92
79.212.07.33 x 10-138.96
Notes:
   a  Gas-liquid system analysis parameter, from calibration measurements.

Method/Apparatus/Procedure:
   The concentration of water in the organic-rich phase was determined radiometrically using tritium labelled water. A full description of the apparatus and method used is given in the paper. 

Source and Purity of Materials:
   (1) Distilled (compiler).
   (2) Source and purity not given.

Estimated Errors:
   Solubility: Not specified.
   Temperature: ± 0.5 K (compiler).