IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: 2-Ethyl-1-hexanol with Decahydronaphthalene (cis + trans) (decalin, bicyclo[4.4.0]decane) and Water

Components:
   (1) Water; H2O; [7732-18-5]  NIST Chemistry WebBook for detail
   (2) 2-Ethyl-1-hexanol; C8H18O; [104-76-7]  NIST Chemistry WebBook for detail
   (3) Decahydronaphthalene (cis+ trans) (decalin, bicyclo [4.4.0]decane); C10H18; [91-17-8]  NIST Chemistry WebBook for detail

Original Measurements:
   Ruiz, F.; Gomis, V.; Botella, R.F., Fluid Phase Equilib. 43, 317-27 (1988).

Variables:
   Temperature = 298 K

Prepared By:
   A. Skrzecz

Experimental Data:   (Notes on the Nomenclature)
  
Compositions of coexisting phases
t/°CT/KMass Fraction w1Mass Fraction w2Mole Fraction x1 (compiler)Mole Fraction x2 (compiler)Comment(s)
25.0298.20.9760.0000.8640.000organic-rich phase
25.0298.20.7860.1980.7450.155organic-rich phase
25.0298.20.5930.3960.5990.331organic-rich phase
25.0298.20.3970.5970.4270.531organic-rich phase
25.0298.20.1990.7980.2270.754organic-rich phase
25.0298.20.0001.0000.0001.000organic-rich phase
25.0298.20.02420.000 85 0.999 (a)0.000 1340.000 00water-rich phase
25.0298.20.01670.000 70 0.9990.000 1100.000 00water-rich phase
25.0298.20.01100.000 59 0.9990.000 0930.000 00water-rich phase
25.0298.20.00610.000 42 1.0000.000 0660.000 00water-rich phase
25.0298.20.00260.000 40 1.0000.000 0630.000 00water-rich phase
25.0298.20.00000.000 00 1.000 (b)0.000 0000.000 00water-rich phase
Notes:
   a  Result of phase equilibrium measurement of binary system 2-ethyl-1-hexanol-water.
   b  Result of phase equilibrium measurement of binary system decahydronaphthalene-water.

Method/Apparatus/Procedure:
   The analytical method was used. Mixtures of known overall compositions, by weight, were stirred intensely and allowed to settle for 2 h at constant temperature bath. Samples of each phase were taken and analyzed by glc method with 1-propanol as internal standard. (1-propanol also prevented phase separation). Analytical conditions: column 2 m x 3 mm, packed with Chromosorb 101 100/120, temp. 190°C, thermal conductivity detector for the organic phase, flame  ionization detector for aqueous phase, helium flow rate-40 mL/min. Decahydronaphthalene was reported to be undetectable in the organic phase.

Source and Purity of Materials:
   (1) Merck; used as received; <0.2 wt % impurities by glc.
   (2) Merck; used as received; mixture of cis-and trans-isomers.
   (3) Source not reported.

Estimated Errors:
   Solubility: Not reported.
   Temperature: Temp. ±0.1°C.