Home
Introduction
Search Menu
IUPAC Series (PDF)
Reference
Version History
About the Project
Disclaimer
Contact Us
Acknowledgements
IUPAC-NIST Solubility Database
NIST Standard Reference Database 106
Solubility System:
Carbon dioxide with Polyimide Ultem
Components:
(1) Polyimide Ultem; ; [61128-24-3]
NIST Chemistry WebBook
for detail
(2) Carbon dioxide; CO2; [124-38-9]
NIST Chemistry WebBook
for detail
Original Measurements:
K.I. Okamoto, K. Tanaka, O. Yokoshi, K. Hidetoshi and A. Nakamura, Intern. Congress on Membranes (ICOM-87), 9-15, Tokyo (1987).
Variables:
Temperature = 353 K
Pressure = 0-3.0 MPa
Prepared By:
Yu. P. Yampol'skii
Experimental Data:
(Subscripts 1,2,3, ..., in column headings refer to components 1,2,3, ...)
Dual-mode sorption parameters for carbon dioxide
Henry's law constant, K [cm
3
(STP)/cm
3
atm]
Langmuir's parameter, C
H
[cm
3
(STP) cm
-3
]
Affinity Coefficient b [atm
-1
]
0.527
6.1
0.286
Method/Apparatus/Procedure:
Equilibrium sorption was measured by the pressure decay method using a dual-volume sorption cell.
Source and Purity of Materials:
Commercial sample of Ultem-1000 (General Electric Co) had a density 1.289 g/cm
3
, glass transition temperature 488 K, and had an amorphous structure.
Estimated Errors: