IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Nitromethane with 3-Methyl-1-hexene

Components:
   (1) Nitromethane; CH3NO2; [75-52-5]  NIST Chemistry WebBook for detail
   (2) 3-Methyl-1-hexene; C7H14; [3404-61-3]  NIST Chemistry WebBook for detail

Original Measurements:
   Riccardi, R.; Franzosini, P.; Rolla, M., Z. Naturforsch. 23A, 1816-8 (1968).

Variables:
   Temperature = 331 K to 346 K

Prepared By:
   V. P. Sazonov

Experimental Remarks:

   The numerical data were not included in the original publication but were provided by Professor R. Riccardi at the request of the compiler.

Experimental Data:   (Notes on the Nomenclature)
  
Mutual solubility of nitromethane and 3-methyl-1-hexene
t/°CT/K102 * Mass Fraction w1 (compiler) Mole Fraction x1Comment(s)
57.4330.6--Hydrocarbon-rich phase
57.4330.680.60.870Nitromethane-rich phase
65.9339.1--Hydrocarbon-rich phase
65.9339.173.90.820Nitromethane-rich phase
66.9340.124.90.348Hydrocarbon-rich phase
66.9340.1--Nitromethane-rich phase
68.9342.1--Hydrocarbon-rich phase
68.9342.167.90.773Nitromethane-rich phase
69.1342.327.50.379Hydrocarbon-rich phase
69.1342.3--Nitromethane-rich phase
70.3343.533.30.445Hydrocarbon-rich phase
70.3343.5--Nitromethane-rich phase
71.1344.3--Hydrocarbon-rich phase
71.1344.362.50.728Nitromethane-rich phase
71.9345.139.80.515Hydrocarbon-rich phase
71.9345.1--Nitromethane-rich phase
72.4345.645.50.573Hydrocarbon-rich phase
72.4345.654.90.662Nitromethane-rich phase
72.4345.6--Hydrocarbon-rich phase
72.4345.650.60.622Nitromethane-rich phase
72.4345.6--Hydrocarbon-rich phase
72.4345.6- (UCST)-Nitromethane-rich phase
Method/Apparatus/Procedure:
   The synthetic method1 was used. Tubes were filled under vacuum with known masses of degassed and moisture-free components, sealed, and then placed in a thermostat bath filled with paraffin oil. The mixtures in the tubes were shaken by a Chemap vibromixer type E-1. Temperatures were measured with Degussa Pt resistance thermometers, which were checked against standards. Phase changes (cloud points) were observed as mixtures were cooled.

Source and Purity of Materials:
   (1) Fluka AG; purity 99 mole %; fractionally distilled, degassed and finally distilled through a P2O5 filled tube.
   (2) Fluka AG; purity 99 mole %; purification as above.

Estimated Errors:

   Temperature: reproduced better than 0.1 K.

References:
   1 P. Franzosini, Z. Naturforsch. 18A, 224 (1963).