IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Sodium formate with Sodium nitrate

Components:
   (1) Sodium formate; NaCHO2; [141-53-7]  NIST Chemistry WebBook for detail
   (2) Sodium nitrate; NaNO3; [7631-99-4]  NIST Chemistry WebBook for detail

Original Measurements:
   Berchiesi, M.A.; Cingolani, A.; Berchiesi, G., J. Chem. Eng. Data 17, 61-4 (1972).

Variables:


Prepared By:
   G. D. Andrea

Experimental Remarks:

   Note 1: There is a eutectic at 191 ºC and 100x2 = 48.1.
Note 2: There is a peritectic at 204 ºC and 100x2 = 34.4. The intermediate compound is Na4(CHO2)3NO3 and melts incongruently.

Experimental Data:   (Notes on the Nomenclature)
(Please see footnotes following the table(s).)
  
t/°CT/KMole Fraction2
257.50530.65  0
249.50522.65  5.17
242.73515.88  9.88
237.58510.7312.69
234.43507.5815.04
231.65504.8016.59
229.03502.1818.12
226.58499.7319.41
226.13499.2820.08
223.98497.1321.53
221.35494.5022.78
219.85493.0024.00
217.73490.8826.08
215.08488.2327.19
213.55486.7028.04
213.05486.2028.61
210.30483.4530.07
207.54480.6932.03
205.85479.00  33.07
204.50477.65  33.99
203.50476.65  35.98
202.13475.28  38.09
201.25474.40  39.99
199.25472.40  42.01
195.38468.53  44.96
193.50466.65  46.61
192.10465.25  48.57
195.75468.90  49.93
200.87474.02  51.67
208.93482.08  55.09
220.70493.85  60.01
243.03516.18  70.02
263.95537.10  79.90
284.98558.13  90.04
306.00579.15100.00
Notes:
   a  The T/K values were calculated the compiler.

Method/Apparatus/Procedure:
   A visual method, supplemented by DSC measurements was used. Salt(s) melted in a Pyrex device1 were placed in a furnace whose temperature was controlled by a Chromel-Alumel thermouple connected to a L&N CAT control unit. The temperature of the melt was measured by a second thermouple checked by comparison with a certified Pt resistance thermometer and a L&N K-5 potentiometer.

Source and Purity of Materials:
   C. Erba (Milan, Italy) materials, at least 99% pure, were dried before being used.

Estimated Errors:
   Solubility: No information is given.
   Temperature: Accuracy of temperature measurement was ± 0.03 K.

References:
   1M. Braghetti, D. Leonesi, and P. Franzosini, Ric. Sci. 38, 116 (1968).