IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Acetonitrile-d3 with Water-d3

Components:
   (1) Water-d2; D2O; [7789-20-0]  NIST Chemistry WebBook for detail
   (2) Acetonitrile-d3; C2D3N; [2206-26-0]  NIST Chemistry WebBook for detail

Original Measurements:
   Szydlowski, J.; Szykula, M., Fluid Phase Equilib. 154, 79 (1999).

Variables:
   Temperature = 255 K to 279 K

Prepared By:
   Valerii P. Sazonov

Experimental Remarks:

   UCST was reported at 279.244 ± 0.006 K at x1c = 0.360 ± 0.003 (100 w1 = 55.3, compiler).

Experimental Data:   (Notes on the Nomenclature)
  
Mutual solubility of acetonitrile-d3 (1) and water-d2 (2)
t/°CT/K102 * Mass Fraction w1 (compiler) Mole Fraction x1Comment(s)
-18.515254.635--Water-d2-rich phase
-9.774263.376--Water-d2-rich phase
-6.481266.66928.00.150Water-d2-rich phase
-5.531267.619--Water-d2-rich phase
-1.591271.559--Water-d2-rich phase
1.619274.769--Water-d2-rich phase
2.036275.18635.60.201Water-d2-rich phase
3.615276.765--Water-d2-rich phase
5.027278.177--Water-d2-rich phase
5.098278.24842.60.252Water-d2-rich phase
5.728278.878--Water-d2-rich phase
5.949279.09948.50.300Water-d2-rich phase
6.095279.24554.10.349Water-d2-rich phase
-18.515254.63590.00.804Acetonitrile-d3-rich phase
-9.774263.37686.20.739Acetonitrile-d3-rich phase
-6.481266.669--Acetonitrile-d3-rich phase
-5.531267.61983.50.697Acetonitrile-d3-rich phase
-1.591271.55980.30.649Acetonitrile-d3-rich phase
1.619274.76976.40.595Acetonitrile-d3-rich phase
2.036275.186--Acetonitrile-d3-rich phase
3.615276.76572.80.549Acetonitrile-d3-rich phase
5.027278.17768.40.496Acetonitrile-d3-rich phase
5.098278.248--Acetonitrile-d3-rich phase
5.728278.87864.60.453Acetonitrile-d3-rich phase
5.949279.099--Acetonitrile-d3-rich phase
6.095279.245--Acetonitrile-d3-rich phase
Method/Apparatus/Procedure:
   The synthetic method was used with a simplified version of the apparatus described in work.1 Temperature was changed at the rate < 0.01 K/min; there was no visible influence of the rate on the transition temperature up to the rate 0.1 K/min. Due to the very weak turbidity a long capillary cell was employed. A 5-mW Polythec HeNe laser was used as a probe for detecting the phase separation.

Source and Purity of Materials:
   (1) Sigma; 99.5 % D; carefully dried over 5 Å molecular sieves; not purified.
   (2) From Institute of Atomic Energy, Isotope Distribution Center; 99.92 % D; twice distilled.

Estimated Errors:

   Temperature: ± 5 mK

References:
   1. J. Szydlowski, L. P. Rebelo, and W. A. Van Hook, Rev. Sci. Instrum. 63, 1717 (1992).