IUPAC-NIST Solubility Database
NIST Standard Reference Database 106


Glass Ball as Bullet Solubility System: Acetonitrile with Hexadecyl esters

Components:
   (1) Hexadecyl esters; C18H36O2 - C34H68O2; []  NIST Chemistry WebBook for detail
   (2) Acetonitrile; C2H3N; [75-05-8]  NIST Chemistry WebBook for detail

Original Measurements:
   Schmid, H.H.O.; Mangold, H.K.; Lundberg, W.O.; J. Am. Oil Chem. Soc. 42, 372 (1965).

Variables:
   Temperature = 321 K to 426 K

Prepared By:
   Valerii P. Sazonov

Experimental Data:   (Notes on the Nomenclature)
  
Upper critical solution temperatures of the systems acetonitrile (1) + hexadecyl ester (2)
t/°CT/KChemical Name
36.0309.2Hexadecyl ethanoate; C18H36O2; [629-70-9]
68.0331.2Hexadecyl butanoate; C20H40O2; [6221-99-4]
89.0362.2Hexadecyl hexanoate; C22H44O2; [14331-11-4]
104.0377.2Hexadecyl octanoate; C24H48O2; [29710-31-4]
118.0391.2Hexadecyl decanoate; C26H52O2; [29710-34-7]
130.0403.2Hexadecyl dodecanoate; C28H56O2; [20834-06-4]
140.5413.7Hexadecyl tetradecanoate; C30H60O2; [2599-01-1]
150.5423.7Hexadecyl hexadecanoate; C32H64O2; [540-10-3]
159.5432.7Hexadecyl octadecanoate; C34H68O2; [1190-63-2]
Method/Apparatus/Procedure:
   The synthetic method was used. A Reichert microscope, type RCH, with a heating stage was used. A 26 x 38 mm slide was adapted to hold capillaries on the stage. Two glass strips were glued, using water glass, to the slide, leaving a 0.5 mm channel. The slide was then placed in the adjustable device of the heating stage. (1) and (2) were put into capillary tubing (0.2 to 0.3 mm diameters) by dipping consecutively into both liquids. The height of the liquid was 7 to 10 mm. Room temperature solids were melted on a glass slide over a micro burner. The capillary was sealed at both ends to a length of 30 to 35 mm, then inserted in to the channel on the slide and heated on the stage. The UCST was determined by following the appearance and disappearance of the meniscus.

Source and Purity of Materials:
   (1) Baker Chemical Co.; reagent, No. 9011; n(20 °C, D) = 1.3445, d(20 °C, 4 °C) = 0.780.
   (2) Not specified.

Estimated Errors:

   Temperature: ± 0.5 K.